The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.
AAS Flame Atomic Absorption Spectrophotometer

Specification
|
Model |
LTS-AAS3604 |
LTS-AAS3608 |
LTS-AAS3618 |
|
|
Optics System |
Type |
Single beam |
Single Beam |
Double Beam |
|
Monochromator |
Anaberration C-T type, focal length 350mm |
|||
|
Dispersing element |
optical grating 1800 bars /mm, flicker wavelength 250nm |
|||
|
Spectral bandwidth (nm) |
0.1、0.2、0.4、0.7、1.4、2nm six grades automatic switchover |
|||
|
Wavelength range (nm) |
185-900nm |
|||
|
Wavelength indication error |
±0.3 nm |
±0.2 nm |
±0.15 nm |
|
|
Wavelength repeatability (nm) |
≤0.1nm |
≤0.1nm |
≤0.05nm |
|
|
Spectral bandwidth deviation |
±0.02 nm |
±0.02 nm |
±0.02 nm |
|
|
Light point |
4 |
8 |
8 |
|
|
Element lamp type |
Common element lamp |
Ordinary element lamp |
Ordinary, high-performance element lamp |
|
|
Photometric Property |
Reading mode |
Transmittance, absorbance, concentration |
||
|
Photometric Range |
0-125%,-0.1-3.00A |
|||
|
Cu static baseline drift |
±0.004A/30min |
±0.003A/30min |
±0.002A/30min |
|
|
Cu dynamic baseline shift |
±0.006A/15min |
±0.005A/15min |
±0.004A/15min |
|
|
Background correction |
Deuterium lamp background correction capability >=30 times (1Abs) |
Deuterium lamp >= 40x (1Abs) |
Deuterium lamp >= 40x (1Abs) |
|
|
Flame Analysis |
Characteristic concentration (Cu) |
≤0.04ug/ml |
≤0.035ug/ml |
≤0.02ug/ml |
|
Detection limit(Cu) |
≤0.008ug/ml |
≤0.006ug/ml |
≤0.004ug/ml |
|
|
Repeatability |
RSD≤1% |
RSD≤0.6% |
RSD≤0.5% |
|
|
Acetylene flow regulation |
Automatic 12 grades |
|||
|
Air assisted air conditioning |
Automatic 4 grades |
|||
|
Burner lift |
Automatic rising-lowering |
|||
|
Burner |
Metal titanium burner |
|||
|
Atomizer |
High efficiency glass atomizer |
|||
|
Atomizing chamber |
Corrosion-resistant material atomization chamber |
|||
|
Safety precautions |
Abnormal pressure protection of flame gas and auxiliary gas |
|||
|
Data processing |
Measurement mode |
Flame method, hydride generation-atomic absorption method, flame emission method |
||
|
Concentration calculation method |
Standard curve method (6 linear and nonlinear fitting methods), standard addition method, interpolation method |
|||
|
Number of repeated measurements |
1-30 times, calculate and give the mean, standard deviation and relative standard deviation of absorbance and concentration |
|||
|
Report printing |
Parameter printing, data result printing |
|||
|
Others |
Computer |
circumscribed |
||
|
Overall dimensions |
830*650*560 |
830*650*560 |
830*650*560 |
|
|
Weight |
90Kg |
90Kg |
95Kg |
|
|
Power |
Voltage 220V±22V, frequency 50Hz ±1Hz |
|||
|
Operating temperature |
10℃~30℃ |
|||
|
Operating Humidity |
40%~85% |
|||
Feature
1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full-band deuterium lamp background correction technology and high-performance self-priming dual background correction.
4. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click.
5. Advanced 360-degree rotation design of lamp position.
6. Novelly designed atomizer and intelligent lifting.
7. Simple, professional, automatic and fully operational RG-WinAAS workstation software under MS Window system.