PRODUCT


Atomic Absorption Spectrophotometer - Flame & Graphite Furnace


The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

Category:

Products

Spectrophotometer

Atomic Absorption Spectrophotometer

WhatsApp:


  • Product Description
  • Company Profile
  • Packing and shipping
    • Commodity name: Atomic Absorption Spectrophotometer - Flame & Graphite Furnace
    • Commodity ID: LTS-AAS3638;LTS-AAS3668

    The atomic absorption spectrophotometer uses excellent all-band deuterium lamp background correction technology. High performance self-priming double background correction; The comprehensive and safe intelligent gas control module and the advanced lamp position eight lamp stand achieve 360 degree rotation design.

     Atomic Absorption Spectrophotometer - Flame & Graphite Furnace

     

     

    Specification

    Model LTS-AAS3638 LTS-AAS3668
    Optical system  Type Single beam Double Beam
    Monochromator Anaberration C-T type, focal length 350mm
    Dispersing element optical grating 1800 bars /mm, flicker wavelength 250nm
    Spectral bandwidth (nm) 0.1、0.2、0.4、0.7、1.4、2nm six grades  automatic switchover
    Wavelength range (nm) 185-900nm
    Wavelength indication error ±0.2 nm ±0.15 nm
    Wavelength repeatability (nm) ≤0.1nm ≤0.05nm
    Spectral bandwidth deviation ±0.02 nm ±0.02 nm
    Light point 8
    Element lamp type Common element lamp Ordinary, high-performance element lamp
    Photometric Property   Reading mode Transmittance, absorbance, concentration
    Photometric Range 0-125%,-0.1-3.00A
    Cu static baseline drift ±0.003A/30min ±0.002A/30min
    Cu dynamic baseline shift ±0.005A/15min ±0.004A/15min
    Background correction Deuterium lamp>=40 times (1Abs) Deuterium lamp >= 40x (1Abs)
    Self-priming >= 80x (1Abs)
    Flame Analysis  Characteristic concentration (Cu) ≤0.035ug/ml ≤0.02ug/ml
    Detection limit(Cu) ≤0.006ug/ml ≤0.004ug/ml
    Repeatability RSD≤0.6% RSD≤0.5%
    Acetylene flow regulation Automatic 12 grades
    Air assisted air conditioning Automatic 4  grades
    Burner lift Automatic rising-lowering
    Burner Metal titanium burner
    Atomizer High efficiency glass atomizer
    Atomizing chamber Corrosion-resistant material atomization chamber
    Safety precautions Abnormal pressure protection of flame gas and auxiliary gas
    Graphite furnace Analysis Characteristic quantity Cd characteristic quantity ≤0.6pg
    Cu characteristic quantity ≤20pg
    Cd characteristic quantity ≤0.5pg
    Cu characteristic quantity ≤20pg
    Detection limit Cd detection limit ≤1.0pg
    Cu detection limit ≤25pg
    Cd detection limit ≤0.8pg
    Cu detection limit ≤25pg
    Repeatability(Cd) RSD≤3% RSD≤2.5%
    Graphite furnace heating range Room temperature ~ 3000℃
    High power heating range 1500℃~3000℃
    Ramp and hold time 1s~255s
    heating rate Maximum heating rate 2000℃/ s
    Atomization heating method Light controlled heating, time controlled heating, general heating
    Protective air flow outside the tube 1 L/min
    Protective air flow in the tube 4 adjustable  levels  (0, 50, 200, 250ml/min flow rate)
    safety precautions Cooling water flow, protective air pressure, furnace body temperature, power supply temperature, graphite tube installation alarm
    Data processing  Measurement mode Flame method, graphite furnace method, hydride generation-atomic absorption method, flame emission method
    Concentration calculation method Standard curve method (6 linear and nonlinear fitting methods), standard addition method, interpolation method
    Number of repeated measurements 1-30 times, calculate and give the mean, standard deviation and relative standard deviation of absorbance and concentration
    Report printing Parameter printing, data result printing
    Others Computer circumscribed
    Overall dimensions 830*650*560mm
    Weight 120Kg 125Kg
    Power Voltage 220V±22V, frequency 50Hz ±1Hz
    Operating temperature 10℃~30℃
    Operating humidity 40%~85%

     

     

     

    Feature

    1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.

    2. Comprehensive and safe intelligent gas control module.

    3. Excellent full-band deuterium lamp background correction technology and high-performance self-priming dual background correction.

    4. Fully automatic instrument control, the light source supports high-performance element lamps, and can be quickly completed with one click.

    5. Advanced eight-position lamp holder with 360-degree rotating design.

    6. Novelly designed atomizer and intelligent lifting.

    7. Simple, professional, automatic and fully operational RG-WinAAS workstation software under MS Window system.

     
    Oil free mute vacuum compressor
    No need for engine oil lubrication, clean and environmentally friendly

     
    Eight lamp holders
    The position of the hollow cathode lamp can be adjusted in all directions, and the instrument lamp position eight lamp stand adopts a unique design to realize 360 degree rotation
     
     
    Application range of atomic absorption spectrometry
    Be committed to providing advanced technical solutions for various analytical fields
     
    Wide range of application
    Used in various fields such as metallurgy, geology, chemical industry, agriculture, medicine, and environmental protection
     